Southwire 69114701 12 AWG 2 Conductor Stranded Metal Clad 600V 250 ft. SLVR

UPC: 032886347559 | Harmonization / Schedule B : 8544.49.3080

Country of Origin: | Shipping Weight:

Original price $440.99 - Original price $440.99
Original price
$440.99
$440.99 - $440.99
Current price $440.99
Metal Clad Armored Cable, Trade Designation MC, Wire Size 12 AWG, Number of Conductors 2 with Insulated CU Ground, Wire Color Black/Green/White, Jacket Color Silver, Length 250 ft, Conductor Design Stranded, Jacket Material Aluminum, Insulation Material Nylon, PVC, Nominal Outside Dia. 0.494 in, Packaging Coil, Voltage 600 V, Temp. Rating -14 Degrees to 90 Degrees C Dry
Number of Conductors 2 with Ground
Jacket Color Silver
Jacket Material Aluminum
Item Metal Clad Armored Cable
Cable Type - Wire and Cable MC
Standards UL 83, 1569, 1685, NEC Article 330, Federal Specification A-A59544 (Formerly J-C-30B), FT4/IEEE 1202, Vertical Cable Tray Flame Test, Listed for Use In UL 1, 2 and 3 Hour Through Penetration Firestop Systems
Jacket Material (Wire and Cable) Aluminum
Jacket Material - Wire and Cable Aluminum
Stranded / Solid Stranded
Application Indoor
Voltage 600 V
Wire and Cable Item Metal Clad Armored Cable
Temp. Rating -14 Degrees to 90 Degrees C Dry
Wire Color Black/Green/White
Max. Amps 20
Cable Type (Wire and Cable) MC
Trade Designation MC
Insulation Material Nylon, PVC
Conductor Design Stranded
Packaging Coil
Product Type Metal Clad Armored Cable
Nom. Od (Mils) 508mils
Construction ConstructionSouthwire Armorlite® Type MC Cable is constructed with soft-drawn copper, Type THHN/THWN conductors rated 90°C dry available in sizes 14 AWG through 2 AWG, and a green insulated grounding conductor. The conductors are cabled together and a binder tape bearing the print legend is wrapped around the assembly. Aluminum interlocking armor is applied over the assembly.
No. of Strands 19
Insulation Thickness (Mils) 15mils
No. of Conductors 2
Applications ApplicationSouthwire Armorlite® Type MC Cable is suitable for use as follows:Branch, feeder and service power distribution in commercial, industrial, institutional, and multiresidential buildings.Fished or embedded in plaster.Concealed or exposed installationsEnvironmental air-handling spaces per NEC 300.22 (C).Places of Assembly per NEC 518.4 and theaters per NEC 520.5.Installation in cable tray and approved raceways.Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations.
Package Quantity 1