Skip to content

Schneider LC1D150G7 IEC Magnetic Contactor Non-Reversing, 3 Poles, 150 A, 120V AC Coil, 1NO/1NC

UPC: 785901214519 | Harmonization / Schedule B : 8536.49.0065

Country of Origin: | Shipping Weight:

Original price $1,245.93 - Original price $1,245.93
Original price
$1,245.93
$1,245.93 - $1,245.93
Current price $1,245.93
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 120V AC, Number of Poles 3, Full Load Current - Inductive 150 A, Full Load Current - Resistive 200 A, Reversing Capability Non-Reversing, Overall Height 6.22 in, Overall Width 0.47 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
Full Load Amps-Inductive 150 A
Action Non-Reversing
Full Load Amps-Resistive 200 A
Number of Poles 3
Coil Volts 120 V AC
Reversing No
HP @ 3 Phase - 208V 40 hp
HP @ 3 Phase - 240V 50 hp
HP @ 3 Phase - 480V 100 hp
HP @ 3 Phase - 575V 125 hp
Aux. Contact Configuration 1NO/1NC
Enclosure NEMA Rating No Enclosure
Hz 50/60
Frame / Series / Class / Code TeSys
Auxiliary Contact Form 1NO/1NC
Standards BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
Series TeSys Deca
Rated Breaking Capacity 1400 A @ 440V
Mounts On Plate, Rail
Shock Resistance 15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open)
Electrical Durability 0.85 Mcycles (150 A, AC-3, Less than 440 V); 1 Mcycles (200 A, AC-1, Less than 440 V); 0.85 Mcycles (150 A, AC-3e, Less than 440 V)
Control Circuit Voltage Limits Drop-Out AC: 0.3 to 0.5 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.15 Uc (at -40-55°C 50/60 Hz), 1 to 1.15 Uc (at 55-70°C 50/60 Hz)
Features Built-In Bi-Directional Peak Limiting Diode Suppressor
Inrush VA 280 to 350 VA
Hold VA 2 to 18 VA
IP Rating IP20
Includes Protective Cover Yes
Max. Temperature 850°C
Tightening Torque 1.2 Nm (Control Circuit), 12 Nm (Power Circuit)
Rated Voltage 1000V AC, 300V DC
Mechanical Durability 8 Mcycles
Application Motor Control, Resistive Load
Environmental Attributes Mercury Free, PVC Free, Pollution Degree 3
Impedance 0.6 mOhm
Impulse Withstand Voltage 8 kV
Operating Time 20 to 35 ms (Closing), 40 to 75 ms (Opening)
Switching Voltage 17 V (Signalling Circuit)
Insulation Resistance Range Greater Than 10 MOhms (Signalling Circuit)
Rated Short-Time Withstand Current 250 A (at 40°C for 10 min Power Circuit), 580 A (at 40°C for 1 min Power Circuit), 1200 A (at 40°C for 10 s Power Circuit), 1400 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Max. Operating Watts 40 kW (at 220 to 230V AC 50/60 Hz AC-3), 75 kW (at 380 to 400V AC 50/60 Hz AC-3), 80 kW 415 to (at 440V AC 50/60 Hz AC-3), 90 kW (at 500V AC 50/60 Hz AC-3), 100 kW (at 660 to 690V AC 50/60 Hz AC-3), 75 kW (at 1000V AC 50/60 Hz AC-3), 22 kW (at 400V AC 50/60 Hz AC-4), 40 kW (at 220 to 230V AC 50/60 Hz AC-3e), 75 kW (at 380 to 400V AC 50/60 Hz AC-3e), 80 kW (at 415 to 440V AC 50/60 Hz AC-3e), 90 kW (at 500V AC 50/60 Hz AC-3e), 100 kW (at 660 to 690V AC 50/60 Hz AC-3e), 75 kW (at 1000V AC 50/60 Hz AC-3e)
Switching Current 5 mA (Signalling Circuit)
Fire Rating UL 94 V1
Overvoltage Category CAT III
Vibration Resistance 4 G (Contactor Closed), 2 G (Contactor Open)
Net Weight 2.5 kg
Rated Insulation Volts 600/1000V (Power Circuit), 600/690V (Signalling Circuit)
Non-Overlap Time 1.5 ms
Electrical Connection Screw Clamp Terminals
Signalling Circuit Frequency 25 to 400 Hz
Watts Loss 3 to 4.5W
Thermal Amperage 200 A (at 60°C Power Circuit)
Fuse Amps 10 A (Signalling Circuit), 315 A (Type 1 Power Circuit), 250 A (Type 2 Power Circuit)
Rated Making Capacity 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1660 A @ 440V (Power Circuit)
Operating Speed 1200 cycles per hr
Electrical Operating Durability 1,000,000, 850,000
NEMA Enclosure Material Not Applicable
Embedded Surge Suppressor Yes
Horsepower @ Three Phase - 208V AC 40 hp
Maximum Operating Temperature 140 Degrees F
Reversing Capability Non-Reversing
Number of Auxillary Contacts 2
Frequency 50/60 Hz
Terminal Connection Type Screw Clamp Terminals
Horsepower @ Single Phase - 240V AC 3 hp
Horsepower @ Three Phase - 240V AC 50 hp
Mounting Style DIN Rail, Plate
Horsepower @ Three Phase - 480V AC 100 hp
Horsepower @ Three Phase - 600V AC 125 hp
Number of Normally Open Main Contacts 3
NEMA Enclosure Rating No Enclosure
Coil Voltage 120V AC
Maximum Voltage Rating 1000V AC
Full Load Current - Resistive 200 A
Mechanical Operating Durability 8,000,000
Full Load Current - Inductive 150 A
Minimum Operating Temperature -40 Degrees F
Resistance Properties Fire Resistant, Insulation Resistant
Phase Three
Contactor Style IEC
Includes Auxiliary Contacts Yes
Rated Operational Current 200 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 150 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 150 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Control Circuit Type AC 50/60 Hz
Product Or Component Type Contactor
Utilisation Category AC-3; AC-1; AC-4; AC-3e
Inrush Power in VA 280 to 350 VA 60 Hz cos phi 0.9 (at 68°F (20°C)); 280 to 350 VA 50 Hz cos phi 0.9 (at 68°F (20°C))
Rated Short Time Withstand Current 250 A 104°F (40°C) - 10 min for power circuit; 580 A 104°F (40°C) - 1 min for power circuit; 1200 A 104°F (40°C) - 10 s for power circuit; 1400 A 104°F (40°C) - 1 s for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit
Motor Power KW 40 kW at 220 to 230 V AC 50/60 Hz (AC-3); 75 kW at 380 to 400 V AC 50/60 Hz (AC-3); 80 kW at 415 to 440 V AC 50/60 Hz (AC-3); 90 kW at 500 V AC 50/60 Hz (AC-3); 100 kW at 660 to 690 V AC 50/60 Hz (AC-3); 75 kW at 1000 V AC 50/60 Hz (AC-3); 22 kW at 400 V AC 50/60 Hz (AC-4); 40 kW at 220 to 230 V AC 50/60 Hz (AC-3e); 75 kW at 380 to 400 V AC 50/60 Hz (AC-3e); 80 kW at 415 to 440 V AC 50/60 Hz (AC-3e); 90 kW at 500 V AC 50/60 Hz (AC-3e); 100 kW at 660 to 690 V AC 50/60 Hz (AC-3e); 75 kW at 1000 V AC 50/60 Hz (AC-3e)
Climatic Withstand IACS E10 exposure to damp heat
Minimum Switching Current 5 mA for signalling circuit
Rated Insulation Voltage Power circuit 600 V CSA; Power circuit 600 V UL; Power circuit 1000 V IEC 60947-4-1; Signalling circuit 690 V IEC 60947-1; Signalling circuit 600 V CSA; Signalling circuit 600 V UL
Rated Impulse Withstand Voltage 8 kV IEC 60947
Maximum Horse Power Rating 40 hp at 200/208 V AC 50/60 Hz for 3 phase motors; 50 hp at 230/240 V AC 50/60 Hz for 3 phase motors; 100 hp at 460/480 V AC 50/60 Hz for 3 phase motors; 125 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Average Impedance 0.6 mOhm - Ith 200 A 50 Hz for power circuit
Hold-In Power Consumption in VA 2 to 18 VA 60 Hz cos phi 0.9 (at 68°F (20°C)); 2 to 18 VA 50 Hz cos phi 0.9 (at 68°F (20°C))
Rated Operational Voltage Power circuit Less than or Equal to 1000 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
Poles Description 3P
Pollution Degree 3
Coil Technology Built-in bidirectional peak limiting diode suppressor
Insulation Resistance Greater than 10 MOhm for signalling circuit
Permissible Ambient Air Temperature Around The Device -40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating
Fire Resistance 1562°F (850°C) IEC 60695-2-1
Pole Contact Composition 3 NO
Contact Compatibility M13
Safety Reliability Level B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1; B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
Control Circuit Voltage 120 V AC 50/60 Hz
Protective Treatment THIEC 60068-2-30
Conventional Free Air Thermal Current 200 A (at 140°F (60°C)) for power circuit
Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
Auxiliary Contact Composition 1 NO + 1 NC
Minimum Switching Voltage 17 V for signalling circuit
Flame Retardance V1 conforming to UL 94
Connections - Terminals Control circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 1 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: solid without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: solid without cable end; Power circuit: connector 1 0.02 to 0.19 in² (10 to 120 mm²) - cable stiffness: flexible without cable end; Power circuit: connector 2 0.02 to 0.08 in² (10 to 50 mm²) - cable stiffness: flexible without cable end; Power circuit: connector 1 0.02 to 0.19 in² (10 to 120 mm²) - cable stiffness: flexible with cable end; Power circuit: connector 2 0.02 to 0.08 in² (10 to 50 mm²) - cable stiffness: flexible with cable end; Power circuit: connector 1 0.02 to 0.19 in² (10 to 120 mm²) - cable stiffness: solid without cable end; Power circuit: connector 2 0.02 to 0.08 in² (10 to 50 mm²) - cable stiffness: solid without cable end
IP Degree Of Protection IP20 front face IEC 60529
Mounting Support Rail; Plate
Contactor Application Motor control; Resistive load
Mechanical Robustness Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 6 Gn for 11 ms)
Associated Fuse Rating 10 A gG for signalling circuit conforming to IEC 60947-5-1; 315 A gG at Less than or Equal to 690 V coordination type 1 for power circuit; 250 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
Maximum Operating Rate 1200 cyc/h 140°F (60°C)
Compatibility Code LC1D
Product Certifications GOST; CCC; RINA; DNV; GL; CSA; LROS (Lloyds register of shipping); UL; BV; UKCA; CE
Heat Dissipation 3 to 4.5 W at 50/60 Hz
Power Dissipation Per Pole 24 W AC-1; 13.5 W AC-3; 13.5 W AC-3e
Operating Altitude 0 to 9842.52 ft (0 to 3000 m)
IRMS Rated Making Capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 1660 A at 440 V for power circuit conforming to IEC 60947