Thermocouple Thermometer, RTD, Thermocouple, Number of Channels 2, 4, Includes NIST-Traceable Certificate No, Accuracy +/-0.4 Percent + 1.8 Degrees F/1 Degrees C, -148 Degrees to 3,092 Degrees F/-100 Degrees to 1,700 Degrees C (Thermocouple), -327.9 Degrees to 1,562 Degrees F/-199.99 Degrees to 850 Degrees C (RTD), (6) AA, 38 mm H x 53 mm W Display with 3.5-Digit Backlit LCD - 20 mm Digit Height
| Manufacturers Warranty Length |
1 yr |
| Display Size |
38 mm H x 53 mm W |
| Digit Height |
20 mm |
| Manufacturer Warranty Length |
1 yr |
| Display Width |
53 mm |
| Display Height |
38 mm |
| Battery Size |
AA |
| Number of Inputs |
4 |
| Probe Connector |
Mini-Type |
| Temp. Range (F) |
-327.9 Degrees to 1,562 Degrees F |
| Temp. Range (C) |
-199.99 Degrees to 850 Degrees |
| Accuracy |
+/-0.4 % + 1.8 Degrees F/1 Degrees C |
| Display |
LCD |
| Battery Type |
(6) AA |
| Memory |
Min/Max |
| Data Logging |
Yes |
| Sampling Rate |
1 to 3600 sec |
| Auto Power Off |
Yes |
| Calibration Certificate Included |
No |
| Includes |
Batteries |
| Data Hold |
Yes |
| Resolution |
0.1 Degrees F/0.1 Degrees C, 1 Degrees F/1 Degrees C |
| Standards |
ISO 9001:2008 |
| Sensor Type |
RTD, Thermocouple |
| Power Source Details |
(6) AA Batteries |
| Backlit |
Yes |
| Included Probes |
Mini-Type |
| For Thermocouple Type |
Type E, Type J, Type K, Type R, Type S, Type T |
| Display Type |
LCD |
| RTD Temperature Range F |
-327.9 Degrees to 1,562 Degrees F |
| Number of Channels |
2, 4 |
| RTD Temperature Range C |
-199.9 Degrees to 850 Degrees C |
| Thermocouple Temperature Range C |
-100 Degrees to 1,150 Degrees C (Type J), -100 Degrees to 1,300 Degrees C (Type K), -100 Degrees to 400 Degrees C (Type T), -100 Degrees to 900 Degrees C (Type E), 0 Degrees to 1,500 Degrees (Type S), 0 Degrees to 1,700 Degrees C (Type R) |
| Humidity Range |
10% to 85% |
| Temperature Meter Type |
Multichannel Thermocouple Temperature Meter with Data Output and Min/Max |
| Functions |
Degrees F/ Degrees C Switchable, 2-Channel RTD Temperature Measurement, 4-Channel Thermocouple Temperature Measurement, Data Hold, Date/Time Stamp, Low Battery Indication, Maximum and Minimum Indicators, Thermocouple Input Type |
| For RTD Type |
Pt 100 |
| Digital Display |
38 mm H x 53 mm W Display with 3.5-Digit Backlit LCD - 20 mm Digit Height |
| RTD Resistance |
100 ohm |
| Data Output Type |
RS-232 |
| Temperature Range |
-148 Degrees to 3,092 Degrees F/-100 Degrees to 1,700 Degrees C (Thermocouple), -327.9 Degrees to 1,562 Degrees F/-199.99 Degrees to 850 Degrees C (RTD) |
| Includes Batteries |
Yes |
| Thermocouple Temperature Range F |
-148 Degrees to 1,652 Degrees (Type E), -148 Degrees to 2,102 Degrees F (Type J), -148 Degrees to 2,372 Degrees F (Type K), -148 Degrees to 752 Degrees F (Type T), 32 Degrees to 2,732 Degrees F (Type S), 32 Degrees to 3,092 Degrees F (Type R) |
| Response Time |
1 sec |
| Includes NIST-Traceable Certificate |
No |
| Includes Wireless Transmission |
No |
| Number of Digits |
3.5 |
| Thermocouple Temperature Fahrenheit - Minimum |
-148 Degrees F (Type E), -148 Degrees F (Type J), -148 Degrees F (Type K), -148 Degrees F (Type T), 32 Degrees F (Type R), 32 Degrees F (Type S) |
| RTD Temperature Fahrenheit - Minimum |
-327.9 Degrees F |
| Relative Humidity - Maximum |
85 % |
| Meter Type |
Handheld |
| Testing Functions |
Min/Max Temperature |
| Sensor Technology |
RTD, Thermocouple |
| Number of Batteries Required |
6 |
| Relative Humidity - Minimum |
10 % |
| Calibration Certificate Type |
Not Certified |
| Includes Low Battery Indicator |
Low Battery Indicator |
| Temperature Resolution F |
0.1 Degrees F below 1,000 Degrees F, 1 Degrees F at or above 1,000 Degrees F |
| Thermocouple Temperature Fahrenheit - Maximum |
1,652 Degrees F (Type E), 2,102 Degrees F (Type J), 2,372 Degrees F (Type K), 2,732 Degrees F (Type S), 3,092 Degrees F (Type R), 752 Degrees F (Type T) |
| Temperature Units |
Celsius, Fahrenheit |
| RTD Temperature Fahrenheit - Maximum |
1,562 Degrees F |
| Country of Origin |
Taiwan (subject to change) |