| Display |
Backlit Digital - 1/4 VGA Dot Matrix |
| Instrument Counts |
50,000 |
| Multimeter Style |
Full Size - Advanced Features |
| Series |
FLUKE (R) Fluke-289/FVF |
| Standards |
CE, CSA, UL |
| Instrument Safety Rating |
CAT IV 600V |
| Includes |
(1 Pair) TL71 Test Leads, (6) AA Batteries (Installed), AC175 Alligator Clips, Quick Reference Guide |
| Batteries Included |
Yes |
| Battery Chemistry |
Alkaline |
| Battery Access |
Yes |
| Weight |
28 oz |
| Interface |
USB |
| Computer Interface Connection Type |
USB |
| Software Included |
Yes |
| Bluetooth Compatible |
Yes |
| Auto Ranging |
Yes |
| Auto Power Off |
Yes |
| Data Hold |
Yes |
| Data Logging |
Yes |
| Peak Hold |
Yes |
| Duty Cycle |
Yes |
| Minimum/Maximum Memory |
Yes |
| Min-Max-Avg Button Included |
Yes |
| Bar Graph Included |
Yes |
| Multiple On-Screen Displays |
Yes |
| Elapse Time Clock |
Yes |
| Time of Day Clock |
Yes |
| Audible Continuity |
Yes |
| Diode Test |
Yes |
| Current Leakage Testing |
No |
| Intrinsically Safe |
No |
| Waterproof |
No |
| Dustproof |
No |
| Thermal Imaging |
No |
| Removable Screen |
No |
| Max. AC Amps |
10 A |
| Maximum AC Current Measurement |
10 A |
| Minimum AC Current Measurement |
0 uA |
| AC Current Measurement Resolution |
500 uA |
| Basic AC Current Accuracy |
+/-0.6% |
| Max. DC Amps |
10 A |
| Maximum DC Current Measurement |
10 A |
| Minimum DC Current Measurement |
0 mA |
| DC Current Measurement Resolution |
500 uA |
| Basic DC Current Accuracy |
+/-0.05% |
| Maximum AC Voltage Measurement |
1,000 V |
| Minimum AC Voltage Measurement |
0 V |
| AC Voltage Measurement Resolution |
50 V |
| Basic AC Voltage Accuracy |
+/-0.4% |
| Maximum DC Voltage Measurement |
1,000 V |
| Minimum DC Voltage Measurement |
0 V |
| DC Voltage Measurement Resolution |
50 V |
| Basic DC Voltage Accuracy |
+/-0.025% + 2 Digits |
| AC Response |
TRMS |
| AC Response Calculation |
TRMS |
| Max. Ohms |
500 megohm |
| Maximum Resistance Measurement |
500 megaohm |
| Minimum Resistance Measurement |
50 ohm |
| Resistance Measurement Resolution |
50 ohm |
| Resistance Measurement Accuracy |
+/-0.05% |
| Capacitance Range |
1 nF to 100 mF |
| Maximum Capacitance Measurement |
100 mF |
| Minimum Capacitance Measurement |
1 nF |
| Capacitance Measurement Resolution |
1 nF |
| Capacitance Measurement Accuracy |
1.00% |
| Instrument Frequency Counter Range |
0.01 Hz to 1 MHz |
| Maximum Frequency Measurement |
1 MHz |
| Minimum Frequency Measurement |
0.01 Hz |
| Frequency Measurement Resolution |
99.999 Hz |
| Frequency Measurement Accuracy |
0.005% |
| Temp. Range |
-328 Degrees to 1994 Degrees F |
| Minimum Temperature Measurement |
-328 Degrees F |
| Maximum Temperature Measurement |
1,994 Degrees F |
| Temperature Measurement Accuracy |
1.00% |
| Minimum Operating Temperature |
-4 Degrees F |
| Maximum Operating Temperature |
131 Degrees F |
| Minimum Storage Temperature |
-40 Degrees F |
| Maximum Storage Temperature |
140 Degrees F |
| Calibration Certificate Included |
No |
| Parameters Measured |
AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Low Input Impedance, Resistance, Temperature (K) |