| UPS Type |
Line Interactive |
| VA Rating - UPS Systems |
3.0 kVA |
| Watts - UPS Systems |
2.88 kW |
| Input Voltage - UPS Systems |
120V AC |
| Output Voltage - UPS Systems |
120V AC |
| Backup Time (Half/Full Load) |
10 min/3 min |
| Outlet Type - UPS Systems |
UPS/Surge |
| Number of Outlets |
9 |
| Medical Grade |
No |
| Includes |
4-Post Installation Kit, PowerAlert Software with USB, Serial and EPO Cables |
| Fax/Modem Line Protection |
No |
| Power Rating |
3kVA |
| Outlet Type |
UPS/Surge |
| Ports |
DB9 Serial, EPO, SNMP/Web Slot, USB (HID Enabled) |
| Mounting - UPS Systems |
Rack/Tower |
| Mounting |
Rack/Tower |
| Hz |
60 Hz |
| Special Features |
Advanced AVR Corrects Brownouts and Overvoltages, Pure Sine Wave Output, Extended Runtime w/BP48V242Utaa, BP48V60Rt3Utaa |
| Transfer Time |
2 msec from Battery to Line, 5 msec from Line to Battery |
| Standards |
CSA, ENERGY STAR Qualified, FCC Part 15 Category A (EMI), NOM, ROHS (Restriction of Hazardous Substances), TAA Compliant, UL 1778 |
| NEMA Plug Configuration |
L5-30P |
| Input Current |
24 A |
| Item |
Smart UPS |
| Output Voltage |
120VAC |
| NEMA Receptacle Configuration |
5-20R, L5-30R |
| Automatic Volts Regulation |
Yes |
| Phase |
1 |
| Footnotes |
3,4,7,8,9 |
| Green Environmental Attribute |
Product Contributes To Reducing Energy Consumption |
| Display Type |
LCD |
| Input Voltage |
120VAC |
| Watts |
2.88kW |
| Green Certification or Other Recognition |
UL1778 (USA)CSA (Canada)NOM (Mexico)FCC Part 15 Category A (EMI)TAA Compliant, RoHS |
| Wattage |
2.88 kW |
| Voltage |
120 |
| Capacity - Batteries |
3000 VA/2880 W |
| Backup/Run Time (Full Load) |
3 Minute/10 Minute |
| Input Connection |
10 ft Cord with NEMA L5-30P Plug |
| Battery Type |
Valve Regulated Lead Acid (VRLA) |
| Output Receptacles |
(8) 5-15/20R; (1) L5-30R |
| High Availability UPS Features |
Hot swappable batteries |
| Frequency Compatibility |
60 Hz |
| Audible Alarm |
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions |
| Nominal Input Voltage(s) Supported |
120V AC |
| High Voltage Transfer to Battery Power (Setpoint) |
145 |
| Internal UPS Replacement Battery Cartridge |
RBC58-2U |
| Half Load Runtime (min.) |
10 min. (1440w) |
| Low Voltage Transfer to Battery Power (Setpoint) |
83 |
| Full Load Runtime (min.) |
3 min. (2880w) |
| Network Management Cards |
SNMPWEBCARD ; TLNETCARD ; WEBCARDLX |
| PowerAlert Software |
For local monitoring via the UPS™s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert |
| AC Mode BTU / Hr. (Full Load) |
409 |
| Output AC Waveform (AC Mode) |
Pure Sine wave |
| Cold Start (Startup in Battery Mode During a Power Failure) |
Cold-start operation supported |
| Output Voltage Regulation (Battery Mode) |
+/-5% |
| Output kVA Capacity (kVA) |
3 |
| Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions |
| AC Suppression Response Time |
Instantaneous |
| Alarm Cancel Operation |
Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available |
| Nominal Output Voltage(s) Supported |
110V; 115V; 120V |
| Audible Noise |
45 dBA maximum, front side 1m |
| Input Phase |
Single-Phase |
| Cooling Method |
Fan |
| Battery Access |
Front panel battery access door |
| Communications Cable |
USB, DB9 and EPO cabling included |
| UPS Input Connection Type |
L5-30P |
| Power Factor |
0.96 |
| Severe Undervoltage Correction |
Input voltages between 83 and 95 are boosted by 24% |
| EMI / RFI AC Noise Suppression |
Yes |
| Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| Installation Form Factors Supported with Optional Accessories |
2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM ) |
| Output kW Capacity (kW) |
2.88 |
| UPS AC Suppression Joule Rating |
570 |
| Communications Interface |
USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface |
| Recommended Electrical Service |
30A 120V |
| Included Mounting Accessory Description |
Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm) |
| Output Watt Capacity (Watts) |
2880 |
| Overvoltage Correction |
Input voltages between 127 and 145 are reduced by 12% |
| Expandable Battery Runtime |
Extended runtime supported via optional external battery packs |
| Installation Form Factors Supported with Included Accessories |
4 post 19 inch rackmount |
| Individually Controllable Load Banks |
Yes |
| Switches |
3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions |
| Rated input current (Maximum Load) |
24A |
| Expandable Runtime |
Yes |
| Battery Replacement Description |
Hot-swappable, replaceable batteries |
| Front Panel LCD Display |
Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options) |
| UPS Certifications |
Meets FCC Part 15 Category A (EMI); TAA Compliant; Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA) |
| Relative Humidity |
0 to 95%, non-condensing |
| Primary Form Factor |
Rackmount |
| Load Management Receptacles |
Two switchable single outlet 5-15/20R load banks |
| UPS Housing Material |
Steel |
| Undervoltage Correction |
Input voltages between 108 and 96 are boosted by 12% |
| Output Voltage Regulation (Line Mode) |
+6%, -14% |
| DC System Voltage (VDC) |
48 |
| External Battery Pack Compatibility |
BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible) |
| Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145 |
| Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
| Output Circuit Breakers |
Two 20A output breakers protect 4 5-15/20R outlets each |
| Nominal Voltage Details |
120v nominal output in battery mode |
| Battery Recharge Rate (Included Batteries) |
Less than 5 hours from 10 to 90% |
| Output Volt Amp Capacity (VA) |
3000 |
| Battery Mode BTU / Hr. (Full Load) |
1736 |
| Output AC Waveform (Battery Mode) |
Pure Sine wave |
| Product Name |
SM3000RMXL2UTAA 3000VA Rack-mountable Line Interactive UPS TAA Compliant |
| TAA Compliant |
Yes |
| Typical Battery Recharge Time |
5 Hour |
| Product Line |
SmartPro |
| Product Type |
Line-interactive UPS |
| Form Factor |
Rack-mountable |
| Receptacle Detail |
1 x NEMA L5-30R, 8 x NEMA 5-15/20R |
| Backup/Run Time (Half Load) |
10 Minute |
| Hot Swappable |
Yes |
| Certifications & Standards |
UL1778 (USA), CSA (Canada), NOM (Mexico), FCC Part 15 Category A (EMI), TAA Compliant |
| Serial Port |
Yes |
| Software Included |
PowerAlert auto-shutdown Software |
| Network Management |
SNMP Manageable |
| Emergency Power OFF |
Yes |
| Plug/Connector Type |
NEMA L5-30P |
| Package Contents |
SmartPro SM3000RMXL2UTAA 3000VA Rack-mountable UPS, PowerAlert Software with USB, DB9 and EPO cabling, 4 x post rackmount installation accessories, Owner's manual with warranty information |
| USB |
Yes |
| Load Capacity |
3000 VA/2880 W |
| UPS Applications |
Large Network |
| Output Capacity (Watts) |
2880 |
| Battery Mode Heat Dissipation (BTU/Hr) @ Full Load |
1736 |
| Runtime Half Load (min.) |
10 min. (1440W) |
| Product Compliance |
FCC Part 15 Class A (USA); Trade Agreements Act (TAA) |
| Product Certifications |
CSA (Canada); NOM (Mexico); UL 1778 |
| Output Capacity (VA) |
3000 |
| Package Includes |
SM3000RMXL2UTAA UPS system;PowerAlert Software with USB, Serial & EPO cabling;4 post rackmount installation kit;Instruction manual |
| Runtime Full Load (min.) |
3 min. (2880W) |