| UPS Type |
Standby |
| VA Rating - UPS Systems |
750.0 VA |
| Watts - UPS Systems |
450.0 W |
| Input Voltage - UPS Systems |
120V AC |
| Output Voltage - UPS Systems |
115V AC, 120V AC |
| Backup Time (Half/Full Load) |
11.5 min/2.5 min |
| Outlet Type - UPS Systems |
(6) Surge, (6) UPS/Surge |
| Number of Outlets |
12 |
| Medical Grade |
No |
| Footnotes |
4,6,9 |
| Includes |
USB cable |
| NEMA Plug Configuration |
5-15p |
| Watts |
450W |
| Outlet Type |
(6) Surge, (6) UPS/Surge |
| Mounting |
Desktop/Tower |
| Ports |
USB (HID enabled) |
| Item |
UPS System |
| Input Current |
10 A |
| Mounting - UPS Systems |
Desktop/Tower |
| Display Type |
LED |
| Automatic Volts Regulation |
No |
| Power Rating |
750VA |
| Green Environmental Attribute |
Product Contributes To Reducing Energy Consumption |
| Transfer Time |
3 msec from Battery to AC, 6 msec from AC to Battery |
| NEMA Receptacle Configuration |
5-15R |
| Special Features |
(4) Built-In ECO Outlets w/Auto Off, Poweralert Software |
| Input Voltage |
120VAC |
| Hz |
60 Hz |
| Phase |
1 |
| Output Voltage |
115V AC |
| Standards |
CSA, FCC Part 15 Category B (EMI), NOM, TAA Compliant, UL 1778 |
| Fax/Modem Line Protection |
Yes |
| Green Certification or Other Recognition |
UL 1778CSAFCC Part 15 Category B (EMI)TAA, RoHS |
| Wattage |
450 W |
| Voltage |
120 |
| Backup/Run Time (Full Load) |
2.50 Minute/11.50 Minute |
| Capacity - Batteries |
750 VA/450 W |
| Input Connection |
6 ft Cord with NEMA 5-15P Plug |
| Battery Type |
Valve Regulated Lead Acid (VRLA) |
| UPS Certifications |
Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI); TAA Compliant |
| DC System Voltage (VDC) |
12 |
| Output AC Waveform (Battery Mode) |
PWM sine wave |
| Network UPS Tools Compatibility |
NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite |
| Relative Humidity |
0 to 95%, non-condensing |
| Half Load Runtime (min.) |
9.4 min. (225w) |
| Input Phase |
Single-Phase |
| Communications Cable |
USB interface cable included |
| Frequency Compatibility |
60 Hz |
| UPS AC Suppression Response Time |
Instantaneous |
| Expandable Runtime |
No |
| Nominal Voltage Details |
115v nominal output in battery mode |
| Installation Form Factors Supported with Included Accessories |
Tower; Ultra-compact desktop; Wallmount |
| Low Voltage Transfer to Battery Power (Setpoint) |
99 |
| Nominal Input Voltage(s) Supported |
120V AC |
| WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
| UPS Input Connection Type |
5-15P; Right-Angled |
| Switches |
Combination switch controls on/off power status and self-test operation; second recessed push-button switch enables ECO outlet switching |
| AC Mode Efficiency Rating (100% Load) |
0.99 |
| Primary Form Factor |
Desktop |
| UPS AC Suppression Joule Rating |
420 |
| LED Indicators |
3 LEDs indicate power status, overload/check battery and ECO-mode status |
| Rated input current (Maximum Load) |
10A |
| UPS Housing Material |
Plastic |
| UPS Dataline Suppression |
1 line TEL/DSL (1 in / 1 out) |
| Output AC Waveform (AC Mode) |
Sine wave |
| Communications Interface |
USB (HID enabled) |
| Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| Audible Alarm |
Audible alarm indicates power-failure and overload status |
| Output Volt Amp Capacity (VA) |
750 |
| Nominal Output Voltage(s) Supported |
110V; 115V; 120V |
| EMI / RFI AC Noise Suppression |
Yes |
| Individually Controllable Load Banks |
No |
| Output Watt Capacity (Watts) |
450 |
| Output Voltage Regulation (Battery Mode) |
+/- 5% |
| AC Mode BTU / Hr. (Full Load) |
3 |
| Output Receptacles |
(12) 5-15R |
| Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
| Battery Recharge Rate (Included Batteries) |
Less than 16 hours from 10% to 90% |
| Cold Start (Startup in Battery Mode During a Power Failure) |
Cold-start operation supported |
| High Voltage Transfer to Battery Power (Setpoint) |
139 |
| PowerAlert Software |
For local monitoring via the UPS™s built-in USB port, download PowerAlert Local software at http://www.tripplite.com/poweralert |
| Recommended Electrical Service |
15A 120V |
| UPS Output Receptacles (Surge Suppression Only) |
6 UPS outlets, 6 surge-only outlets |
| USB |
Yes |
| Plug/Connector Type |
NEMA 5-15P |
| Typical Battery Recharge Time |
20 Hour |
| Dataline Protection |
RJ-11 |
| Receptacle Detail |
6 x NEMA 5-15R |
| Product Series |
ECO |
| Load Capacity |
750 VA/450 W |
| Certifications & Standards |
UL 1778, CSA, FCC Part 15 Category B (EMI), TAA |
| Product Type |
Standby UPS |
| TAA Compliant |
Yes |
| Product Name |
ECO750UPSTAA 750 VA Desktop ECO UPS TAA Compliant |
| Package Contents |
ECO750UPSTAA 750 VA Desktop UPS, USB Cable, Instructional Manual with Warranty Information |
| Backup/Run Time (Half Load) |
11.50 Minute |
| Form Factor |
Desktop |
| Runtime Half Load (min.) |
9.4 min. (225W) |
| High Availability UPS Features |
Surge/noise protection |
| Output Capacity (Watts) |
450 |
| Output Capacity (VA) |
750 |
| Product Certifications |
CSA (Canada); NOM (Mexico); UL 1778 |
| Product Compliance |
FCC Part 15 Class B (USA); Trade Agreements Act (TAA) |
| UPS Applications |
Computer/Peripherals |
| Package Includes |
ECO750UPSTAA TAA Compliant UPS System;USB cable;Instruction manual |
| Runtime Full Load (min.) |
2.8 min. (450W) |