Full Load Amps-Inductive |
18 A |
Full Load Amps-Resistive |
32 A |
Number of Poles |
3 |
Coil Volts |
110 V AC |
Reversing |
No |
HP @ 1 Phase - 120V |
1 hp |
HP @ 1 Phase - 240V |
3 hp |
HP @ 3 Phase - 208V |
5 hp |
HP @ 3 Phase - 240V |
5 hp |
HP @ 3 Phase - 575V |
15 hp |
HP @ 3 Phase - 480V |
10 hp |
Enclosure NEMA Rating |
No Enclosure |
Aux. Contact Configuration |
1NO/1NC |
Hz |
50/60 |
Frame / Series / Class / Code |
TeSys |
Series |
TeSys Deca |
Standards |
BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
Auxiliary Contact Form |
1NO/1NC |
Operating Time |
12 to 22 ms (Closing), 4 to 19 ms (Opening) |
Application |
Motor Control, Resistive Load |
Control Circuit Voltage Limits |
Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
Features |
Without Built-In Suppressor Module |
Overvoltage Category |
CAT III |
Rated Making Capacity |
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 300 A @ 440V (Power Circuit) |
Signalling Circuit Frequency |
25 to 400 Hz |
Electrical Connection |
Screw Clamp Terminals |
Thermal Amperage |
10 A (at 60°C Signalling Circuit), 32 A (at 60°C Power Circuit) |
Tightening Torque |
1.7 Nm |
Switching Current |
5 mA (Signalling Circuit) |
Environmental Attributes |
Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
IP Rating |
IP20 |
Inrush VA |
70 VA |
Operating Speed |
3600 cycles per hr |
Net Weight |
0.33 kg |
Fuse Amps |
10 A (Signalling Circuit), 50 A (Type 1 Power Circuit), 35 A (Type 2 Power Circuit) |
Mounts On |
Plate, Rail |
Electrical Durability |
1.65 Mcycles (18 A, AC-3, Less than 440 V); 1 Mcycles (32 A, AC-1, Less than 440 V); 1.65 Mcycles (18 A, AC-3e, Less than 440 V) |
Vibration Resistance |
4 G (Contactor Closed), 2 G (Contactor Open) |
Hold VA |
7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
Switching Voltage |
17 V (Signalling Circuit) |
Insulation Resistance Range |
Greater Than 10 MOhms (Signalling Circuit) |
Impulse Withstand Voltage |
6 kV |
Watts Loss |
2 to 3W |
Max. Temperature |
850°C |
Rated Breaking Capacity |
300 A @ 440V |
Rated Insulation Volts |
600/690V |
Rated Short-Time Withstand Current |
145 A (at 40°C for 10 s Power Circuit), 240 A (at 40°C for 1 s Power Circuit), 40 A (at 40°C for 10 min Power Circuit), 84 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Impedance |
2.5 mOhm |
Includes Protective Cover |
Yes |
Mechanical Durability |
15 Mcycles |
Shock Resistance |
15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
Max. Operating Watts |
4 kW (at 220 to 230V AC 50/60 Hz AC-3), 7.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 9 kW (at 415 to 440V AC 50/60 Hz AC-3), 10 kW (at 500V AC 50/60 Hz AC-3), 10 kW (at 660 to 690V AC 50/60 Hz AC-3), 4 kW (at 400V AC 50/60 Hz AC-4), 4 kW (at 220 to 230V AC 50/60 Hz AC-3e), 7.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 9 kW (at 415 to 440V AC 50/60 Hz AC-3e), 10 kW (at 500V AC 50/60 Hz AC-3e), 10 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
Fire Rating |
UL 94 V1 |
Rated Voltage |
690V AC, 300V DC |
Non-Overlap Time |
1.5 ms |
Includes Auxiliary Contacts |
Yes |
Horsepower @ Three Phase - 600V AC |
15 hp |
Reversing Capability |
Non-Reversing |
Contactor Style |
IEC |
Minimum Operating Temperature |
-40 Degrees F |
Number of Normally Open Main Contacts |
3 |
Coil Voltage |
110V AC |
Mounting Style |
DIN Rail, Plate |
Maximum Voltage Rating |
690V AC |
Frequency |
50/60 Hz |
Resistance Properties |
Fire Resistant, Insulation Resistant |
Number of Auxillary Contacts |
2 |
Embedded Surge Suppressor |
No |
Horsepower @ Single Phase - 240V AC |
3 hp |
Full Load Current - Inductive |
18 A |
Phase |
Three |
Mechanical Operating Durability |
15,000,000 |
NEMA Enclosure Rating |
No Enclosure |
Horsepower @ Single Phase - 120V AC |
1 hp |
Maximum Operating Temperature |
140 Degrees F |
Horsepower @ Three Phase - 240V AC |
5 hp |
Terminal Connection Type |
Screw Clamp Terminals |
Electrical Operating Durability |
1,000,000, 1,650,000 |
Horsepower @ Three Phase - 208V AC |
5 hp |
Horsepower @ Three Phase - 480V AC |
10 hp |
Product Certifications |
GL; RINA; UL; CCC; DNV; LROS (Lloyds register of shipping); CSA; GOST; BV; UKCA |
Connections - Terminals |
Control circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: solid without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: solid without cable end; Power circuit: screw clamp terminals 1 0.00 to 0.01 in² (1.5 to 6 mm²) - cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 2 0.00 to 0.01 in² (1.5 to 6 mm²) - cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 6 mm²) - cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 1 0.00 to 0.01 in² (1.5 to 6 mm²) - cable stiffness: solid without cable end; Power circuit: screw clamp terminals 2 0.00 to 0.01 in² (1.5 to 6 mm²) - cable stiffness: solid without cable end |
Pole Contact Composition |
3 NO |
Rated Operational Current |
18 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 32 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 18 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit |
Compatibility Code |
LC1D |
IRMS Rated Making Capacity |
140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 300 A at 440 V for power circuit conforming to IEC 60947 |
Utilisation Category |
AC-1; AC-4; AC-3; AC-3e |
Contact Compatibility |
M2 |
Protective Cover |
With |
Permissible Ambient Air Temperature Around The Device |
-40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating |
Mechanical Robustness |
Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor open 10 Gn for 11 ms); Shocks contactor closed 15 Gn for 11 ms) |
Rated Impulse Withstand Voltage |
6 kV IEC 60947 |
Fire Resistance |
1562°F (850°C) IEC 60695-2-1 |
Operating Altitude |
0 to 9842.52 ft (0 to 3000 m) |
Inrush Power in VA |
70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C)) |
Conventional Free Air Thermal Current |
10 A (at 140°F (60°C)) for signalling circuit; 32 A (at 140°F (60°C)) for power circuit |
Control Circuit Type |
AC 50/60 Hz standard |
Maximum Operating Rate |
3600 cyc/h 140°F (60°C) |
Auxiliary Contacts Type |
Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1 |
Auxiliary Contact Composition |
1 NO + 1 NC |
Rated Insulation Voltage |
Power circuit 690 V IEC 60947-4-1; Power circuit 600 V CSA; Power circuit 600 V UL; Signalling circuit 690 V IEC 60947-1; Signalling circuit 600 V CSA; Signalling circuit 600 V UL |
Maximum Horse Power Rating |
1 hp at 115 V AC 50/60 Hz for 1 phase motors; 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 5 hp at 200/208 V AC 50/60 Hz for 3 phase motors; 5 hp at 230/240 V AC 50/60 Hz for 3 phase motors; 10 hp at 460/480 V AC 50/60 Hz for 3 phase motors; 15 hp at 575/600 V AC 50/60 Hz for 3 phase motors |
Poles Description |
3P |
Minimum Switching Current |
5 mA for signalling circuit |
Average Impedance |
2.5 mOhm - Ith 32 A 50 Hz for power circuit |
Pollution Degree |
3 |
Heat Dissipation |
2 to 3 W at 50/60 Hz |
Climatic Withstand |
IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat |
Motor Power KW |
4 kW at 220 to 230 V AC 50/60 Hz (AC-3); 7.5 kW at 380 to 400 V AC 50/60 Hz (AC-3); 9 kW at 415 to 440 V AC 50/60 Hz (AC-3); 10 kW at 500 V AC 50/60 Hz (AC-3); 10 kW at 660 to 690 V AC 50/60 Hz (AC-3); 4 kW at 400 V AC 50/60 Hz (AC-4); 4 kW at 220 to 230 V AC 50/60 Hz (AC-3e); 7.5 kW at 380 to 400 V AC 50/60 Hz (AC-3e); 9 kW at 415 to 440 V AC 50/60 Hz (AC-3e); 10 kW at 500 V AC 50/60 Hz (AC-3e); 10 kW at 660 to 690 V AC 50/60 Hz (AC-3e) |
Insulation Resistance |
Greater than 10 MOhm for signalling circuit |
Safety Reliability Level |
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Mounting Support |
Plate; Rail |
Contactor Application |
Motor control; Resistive load |
Power Dissipation Per Pole |
2.5 W AC-1; 0.8 W AC-3; 0.8 W AC-3e |
Rated Short Time Withstand Current |
145 A 104°F (40°C) - 10 s for power circuit; 240 A 104°F (40°C) - 1 s for power circuit; 40 A 104°F (40°C) - 10 min for power circuit; 84 A 104°F (40°C) - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit |
Protective Treatment |
THIEC 60068-2-30 |
Rated Operational Voltage |
Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC |
Minimum Switching Voltage |
17 V for signalling circuit |
Flame Retardance |
V1 conforming to UL 94 |
Product Or Component Type |
Contactor |
Control Circuit Voltage |
110 V AC 50/60 Hz |
IP Degree Of Protection |
IP20 front face IEC 60529 |
Associated Fuse Rating |
10 A gG for signalling circuit conforming to IEC 60947-5-1; 50 A gG at Less than or Equal to 690 V coordination type 1 for power circuit; 35 A gG at Less than or Equal to 690 V coordination type 2 for power circuit |
Hold-In Power Consumption in VA |
7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)); 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C)) |