{"product_id":"schneider-lrd14-overload-relay-thermal-protection-3-poles-1no-1nc-phase-loss-sensitivity-7-a-10-a","title":"Schneider LRD14 Overload Relay, Thermal Protection, 3 Poles, 1NO\/1NC, Phase Loss Sensitivity, 7 A – 10 A","description":"\u003cp\u003eTeSys LRD overload relays are designed to be used with TeSys D contactors to make a motor starter. This overload relay can be used with 9 amp through 38 amp TeSys D contactors. These differential thermal overload relays detect over currents in the lines to the motor. When an overcurrent is detected the overload relay working with the contactor will disconnect the power to the motor. This will minimize the damage to the motor windings. This overload relay has an adjustable trip current rating of 7 to 10 amperes. This trip current rating is calibrated per Class 10A. Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine).\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e1.77\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverall Height - Relay\u003c\/th\u003e\n\u003ctd\u003e3.62 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e2.75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e3.62\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBody Height - Relay\u003c\/th\u003e\n\u003ctd\u003e3.62 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBody Depth\u003c\/th\u003e\n\u003ctd\u003e2.76 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBody Width\u003c\/th\u003e\n\u003ctd\u003e1.77 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverall Height\u003c\/th\u003e\n\u003ctd\u003e2.6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBody Height\u003c\/th\u003e\n\u003ctd\u003e2.6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Contact Form\u003c\/th\u003e\n\u003ctd\u003e1NC\/1NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Overload Relay Current Setting\u003c\/th\u003e\n\u003ctd\u003e7:00 AM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Overload Relay Current Setting\u003c\/th\u003e\n\u003ctd\u003e10:00 AM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTrip Class\u003c\/th\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Protection Type\u003c\/th\u003e\n\u003ctd\u003eThermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Voltage Rating\u003c\/th\u003e\n\u003ctd\u003e690V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eCSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, EN 50495, EN\/IEC 60947-4-1, EN\/IEC 60947-5-1, GB\/T 14048.4, GB\/T 14048.5, REACH, RoHS, UL 60947-4-1, UL 60947-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eLC1D09 thru LC1D32 Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTrip Class - Overload\u003c\/th\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensing Method\u003c\/th\u003e\n\u003ctd\u003eBimetallic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFeatures\u003c\/th\u003e\n\u003ctd\u003eSingle Phase Sensitivity; Differential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUse With - Contactors and Starters\u003c\/th\u003e\n\u003ctd\u003eMfr. Series LC1D09 to LC1D32 Contactors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarter Type\u003c\/th\u003e\n\u003ctd\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Certifications\u003c\/th\u003e\n\u003ctd\u003eIEC || UL || CSA || CCC || EAC || BV || RINA || DNV-GL || LROS (Lloyds register of shipping) || ATEX INERIS || UKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDevice Short Name\u003c\/th\u003e\n\u003ctd\u003eLRD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlame Retardance\u003c\/th\u003e\n\u003ctd\u003eV1 conforming to UL 94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAssociated Fuse Rating\u003c\/th\u003e\n\u003ctd\u003e4 A gG signalling circuit || 4 A BS signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical Robustness\u003c\/th\u003e\n\u003ctd\u003evibrations6 Gn IEC 60068-2-6 || shocks15 Gn for 11 ms IEC 60068-2-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNetwork Frequency\u003c\/th\u003e\n\u003ctd\u003e0 to 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Air Temperature For Storage\u003c\/th\u003e\n\u003ctd\u003e-60-70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible Current\u003c\/th\u003e\n\u003ctd\u003e3 A 120 V AC-15 signalling circuit || 0.22 A 125 V DC-13 signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Name\u003c\/th\u003e\n\u003ctd\u003eTeSys LRD || TeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Or Component Type\u003c\/th\u003e\n\u003ctd\u003edifferential thermal overload relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTripping Threshold\u003c\/th\u003e\n\u003ctd\u003e1.14 +\/- 0.06 Ir IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Type\u003c\/th\u003e\n\u003ctd\u003eRed push-button stop || Blue push-button reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClimatic Withstand\u003c\/th\u003e\n\u003ctd\u003eIACS E10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Air Temperature For Operation\u003c\/th\u003e\n\u003ctd\u003e-20-60°C without derating IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Compatibility\u003c\/th\u003e\n\u003ctd\u003eLC1D09 || LC1D12 || LC1D38 || LC1D32 || LC1D25 || LC1D18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNetwork Type\u003c\/th\u003e\n\u003ctd\u003eAC || DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTightening Torque\u003c\/th\u003e\n\u003ctd\u003econtrol circuit 1.7 N.m screw clamp terminals || power circuit 1.7 N.m screw clamp terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDielectric Strength\u003c\/th\u003e\n\u003ctd\u003e1.89 kV 50 Hz IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelay Application\u003c\/th\u003e\n\u003ctd\u003emotor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThermal Protection Adjustment Range\u003c\/th\u003e\n\u003ctd\u003e7-10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThermal Overload Class\u003c\/th\u003e\n\u003ctd\u003eclass 10A IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase Failure Sensitivity\u003c\/th\u003e\n\u003ctd\u003etripping current 130 % of Ir on two phase, the last one at 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003ctd\u003eTeSys || TeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnections - Terminals\u003c\/th\u003e\n\u003ctd\u003econtrol circuit screw clamp terminals 2 1-2.5 mm² flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm² solid without cable end || power circuit screw clamp terminals 1 1.5-10 mm² flexible without cable end || power circuit screw clamp terminals 1 1-4 mm² flexible with cable end || power circuit screw clamp terminals 1 1-6 mm² solid without cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReset Type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP Rating\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompatible with Series\u003c\/th\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting Style\u003c\/th\u003e\n\u003ctd\u003eDirect To Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Operating Temperature\u003c\/th\u003e\n\u003ctd\u003e140 Degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelay Style\u003c\/th\u003e\n\u003ctd\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Connection Type\u003c\/th\u003e\n\u003ctd\u003eScrew Clamp Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Operating Temperature\u003c\/th\u003e\n\u003ctd\u003e-4 Degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Insulation Voltage\u003c\/th\u003e\n\u003ctd\u003ePower circuit 600 V CSA; Power circuit 600 V UL; Power circuit 690 V IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operational Voltage\u003c\/th\u003e\n\u003ctd\u003e690 V AC 0 to 400 Hz power circuit IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConventional Free Air Thermal Current\u003c\/th\u003e\n\u003ctd\u003e5 A signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTrip Clss\u003c\/th\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of Origin\u003c\/th\u003e\n\u003ctd\u003eKorea, Republic of\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":53663662473513,"sku":"KV3DY99","price":139.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3809\/4121\/files\/3DY99_AS02.jpg?v=1789015452","url":"https:\/\/www.kvmtools.com\/products\/schneider-lrd14-overload-relay-thermal-protection-3-poles-1no-1nc-phase-loss-sensitivity-7-a-10-a","provider":"KVM Tools Inc.","version":"1.0","type":"link"}