Schneider LC1D150G7 IEC Magnetic Contactor Non-Reversing, 3 Poles, 150 A, 120V AC Coil, 1NO/1NC
UPC: 785901214519 | Harmonization (Schedule B): 8536.49.0065
SKU KV2MMR5
Original price
$1,245.93
-
Original price
$1,245.93
Original price
$1,245.93
$1,245.93
-
$1,245.93
Current price
$1,245.93
Full Load Amps-Inductive | 150 A |
Action | Non-Reversing |
Full Load Amps-Resistive | 200 A |
Number of Poles | 3 |
Coil Volts | 120 V AC |
Reversing | No |
HP @ 3 Phase - 208V | 40 hp |
HP @ 3 Phase - 240V | 50 hp |
HP @ 3 Phase - 480V | 100 hp |
HP @ 3 Phase - 575V | 125 hp |
Aux. Contact Configuration | 1NO/1NC |
Enclosure NEMA Rating | No Enclosure |
Hz | 50/60 |
Frame / Series / Class / Code | TeSys |
Auxiliary Contact Form | 1NO/1NC |
Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
Series | TeSys Deca |
Rated Breaking Capacity | 1400 A @ 440V |
Mounts On | Plate, Rail |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open) |
Electrical Durability | 0.85 Mcycles (150 A, AC-3, Less than 440 V); 1 Mcycles (200 A, AC-1, Less than 440 V); 0.85 Mcycles (150 A, AC-3e, Less than 440 V) |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.5 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.15 Uc (at -40-55°C 50/60 Hz), 1 to 1.15 Uc (at 55-70°C 50/60 Hz) |
Features | Built-In Bi-Directional Peak Limiting Diode Suppressor |
Inrush VA | 280 to 350 VA |
Hold VA | 2 to 18 VA |
IP Rating | IP20 |
Includes Protective Cover | Yes |
Max. Temperature | 850°C |
Tightening Torque | 1.2 Nm (Control Circuit), 12 Nm (Power Circuit) |
Rated Voltage | 1000V AC, 300V DC |
Mechanical Durability | 8 Mcycles |
Application | Motor Control, Resistive Load |
Environmental Attributes | Mercury Free, PVC Free, Pollution Degree 3 |
Impedance | 0.6 mOhm |
Impulse Withstand Voltage | 8 kV |
Operating Time | 20 to 35 ms (Closing), 40 to 75 ms (Opening) |
Switching Voltage | 17 V (Signalling Circuit) |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Rated Short-Time Withstand Current | 250 A (at 40°C for 10 min Power Circuit), 580 A (at 40°C for 1 min Power Circuit), 1200 A (at 40°C for 10 s Power Circuit), 1400 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Max. Operating Watts | 40 kW (at 220 to 230V AC 50/60 Hz AC-3), 75 kW (at 380 to 400V AC 50/60 Hz AC-3), 80 kW 415 to (at 440V AC 50/60 Hz AC-3), 90 kW (at 500V AC 50/60 Hz AC-3), 100 kW (at 660 to 690V AC 50/60 Hz AC-3), 75 kW (at 1000V AC 50/60 Hz AC-3), 22 kW (at 400V AC 50/60 Hz AC-4), 40 kW (at 220 to 230V AC 50/60 Hz AC-3e), 75 kW (at 380 to 400V AC 50/60 Hz AC-3e), 80 kW (at 415 to 440V AC 50/60 Hz AC-3e), 90 kW (at 500V AC 50/60 Hz AC-3e), 100 kW (at 660 to 690V AC 50/60 Hz AC-3e), 75 kW (at 1000V AC 50/60 Hz AC-3e) |
Switching Current | 5 mA (Signalling Circuit) |
Fire Rating | UL 94 V1 |
Overvoltage Category | CAT III |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Net Weight | 2.5 kg |
Rated Insulation Volts | 600/1000V (Power Circuit), 600/690V (Signalling Circuit) |
Non-Overlap Time | 1.5 ms |
Electrical Connection | Screw Clamp Terminals |
Signalling Circuit Frequency | 25 to 400 Hz |
Watts Loss | 3 to 4.5W |
Thermal Amperage | 200 A (at 60°C Power Circuit) |
Fuse Amps | 10 A (Signalling Circuit), 315 A (Type 1 Power Circuit), 250 A (Type 2 Power Circuit) |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1660 A @ 440V (Power Circuit) |
Operating Speed | 1200 cycles per hr |
Electrical Operating Durability | 1,000,000, 850,000 |
NEMA Enclosure Material | Not Applicable |
Embedded Surge Suppressor | Yes |
Horsepower @ Three Phase - 208V AC | 40 hp |
Maximum Operating Temperature | 140 Degrees F |
Reversing Capability | Non-Reversing |
Number of Auxillary Contacts | 2 |
Frequency | 50/60 Hz |
Terminal Connection Type | Screw Clamp Terminals |
Horsepower @ Single Phase - 240V AC | 3 hp |
Horsepower @ Three Phase - 240V AC | 50 hp |
Mounting Style | DIN Rail, Plate |
Horsepower @ Three Phase - 480V AC | 100 hp |
Horsepower @ Three Phase - 600V AC | 125 hp |
Number of Normally Open Main Contacts | 3 |
NEMA Enclosure Rating | No Enclosure |
Coil Voltage | 120V AC |
Maximum Voltage Rating | 1000V AC |
Full Load Current - Resistive | 200 A |
Mechanical Operating Durability | 8,000,000 |
Full Load Current - Inductive | 150 A |
Minimum Operating Temperature | -40 Degrees F |
Resistance Properties | Fire Resistant, Insulation Resistant |
Phase | Three |
Contactor Style | IEC |
Includes Auxiliary Contacts | Yes |
Rated Operational Current | 200 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 150 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 150 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit |
Control Circuit Type | AC 50/60 Hz |
Product Or Component Type | Contactor |
Utilisation Category | AC-3; AC-1; AC-4; AC-3e |
Inrush Power in VA | 280 to 350 VA 60 Hz cos phi 0.9 (at 68°F (20°C)); 280 to 350 VA 50 Hz cos phi 0.9 (at 68°F (20°C)) |
Rated Short Time Withstand Current | 250 A 104°F (40°C) - 10 min for power circuit; 580 A 104°F (40°C) - 1 min for power circuit; 1200 A 104°F (40°C) - 10 s for power circuit; 1400 A 104°F (40°C) - 1 s for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit |
Motor Power KW | 40 kW at 220 to 230 V AC 50/60 Hz (AC-3); 75 kW at 380 to 400 V AC 50/60 Hz (AC-3); 80 kW at 415 to 440 V AC 50/60 Hz (AC-3); 90 kW at 500 V AC 50/60 Hz (AC-3); 100 kW at 660 to 690 V AC 50/60 Hz (AC-3); 75 kW at 1000 V AC 50/60 Hz (AC-3); 22 kW at 400 V AC 50/60 Hz (AC-4); 40 kW at 220 to 230 V AC 50/60 Hz (AC-3e); 75 kW at 380 to 400 V AC 50/60 Hz (AC-3e); 80 kW at 415 to 440 V AC 50/60 Hz (AC-3e); 90 kW at 500 V AC 50/60 Hz (AC-3e); 100 kW at 660 to 690 V AC 50/60 Hz (AC-3e); 75 kW at 1000 V AC 50/60 Hz (AC-3e) |
Climatic Withstand | IACS E10 exposure to damp heat |
Minimum Switching Current | 5 mA for signalling circuit |
Rated Insulation Voltage | Power circuit 600 V CSA; Power circuit 600 V UL; Power circuit 1000 V IEC 60947-4-1; Signalling circuit 690 V IEC 60947-1; Signalling circuit 600 V CSA; Signalling circuit 600 V UL |
Rated Impulse Withstand Voltage | 8 kV IEC 60947 |
Maximum Horse Power Rating | 40 hp at 200/208 V AC 50/60 Hz for 3 phase motors; 50 hp at 230/240 V AC 50/60 Hz for 3 phase motors; 100 hp at 460/480 V AC 50/60 Hz for 3 phase motors; 125 hp at 575/600 V AC 50/60 Hz for 3 phase motors |
Average Impedance | 0.6 mOhm - Ith 200 A 50 Hz for power circuit |
Hold-In Power Consumption in VA | 2 to 18 VA 60 Hz cos phi 0.9 (at 68°F (20°C)); 2 to 18 VA 50 Hz cos phi 0.9 (at 68°F (20°C)) |
Rated Operational Voltage | Power circuit Less than or Equal to 1000 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC |
Poles Description | 3P |
Pollution Degree | 3 |
Coil Technology | Built-in bidirectional peak limiting diode suppressor |
Insulation Resistance | Greater than 10 MOhm for signalling circuit |
Permissible Ambient Air Temperature Around The Device | -40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating |
Fire Resistance | 1562°F (850°C) IEC 60695-2-1 |
Pole Contact Composition | 3 NO |
Contact Compatibility | M13 |
Safety Reliability Level | B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1; B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Control Circuit Voltage | 120 V AC 50/60 Hz |
Protective Treatment | THIEC 60068-2-30 |
Conventional Free Air Thermal Current | 200 A (at 140°F (60°C)) for power circuit |
Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1 |
Auxiliary Contact Composition | 1 NO + 1 NC |
Minimum Switching Voltage | 17 V for signalling circuit |
Flame Retardance | V1 conforming to UL 94 |
Connections - Terminals | Control circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 1 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: solid without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: solid without cable end; Power circuit: connector 1 0.02 to 0.19 in² (10 to 120 mm²) - cable stiffness: flexible without cable end; Power circuit: connector 2 0.02 to 0.08 in² (10 to 50 mm²) - cable stiffness: flexible without cable end; Power circuit: connector 1 0.02 to 0.19 in² (10 to 120 mm²) - cable stiffness: flexible with cable end; Power circuit: connector 2 0.02 to 0.08 in² (10 to 50 mm²) - cable stiffness: flexible with cable end; Power circuit: connector 1 0.02 to 0.19 in² (10 to 120 mm²) - cable stiffness: solid without cable end; Power circuit: connector 2 0.02 to 0.08 in² (10 to 50 mm²) - cable stiffness: solid without cable end |
IP Degree Of Protection | IP20 front face IEC 60529 |
Mounting Support | Rail; Plate |
Contactor Application | Motor control; Resistive load |
Mechanical Robustness | Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 6 Gn for 11 ms) |
Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1; 315 A gG at Less than or Equal to 690 V coordination type 1 for power circuit; 250 A gG at Less than or Equal to 690 V coordination type 2 for power circuit |
Maximum Operating Rate | 1200 cyc/h 140°F (60°C) |
Compatibility Code | LC1D |
Product Certifications | GOST; CCC; RINA; DNV; GL; CSA; LROS (Lloyds register of shipping); UL; BV; UKCA; CE |
Heat Dissipation | 3 to 4.5 W at 50/60 Hz |
Power Dissipation Per Pole | 24 W AC-1; 13.5 W AC-3; 13.5 W AC-3e |
Operating Altitude | 0 to 9842.52 ft (0 to 3000 m) |
IRMS Rated Making Capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 1660 A at 440 V for power circuit conforming to IEC 60947 |